07.97

7 Drive Machine Data (SIMODRIVE Drive MD)

7.3.2 Drive MD (data description)

Table: Possible current and speed controller cycle combinations

SIN 840C with 611D

controller ...

Current

controller cycle

MD 1000

Speed

controller cycle

MD 1001

Comments

Single-axis performance

125

µ

s

125

µ

s

Default value

Single-axis performance

62.5

µ

s

62,5

µ

s

Minimum

Single-axis performance

125

µ

s

250

µ

s

as from SW 6

Single-axis performance

125

µ

s

500

µ

s

as from SW 6

2-axis performance

125

µ

s

125

µ

s

Default value/minimum

2-axis performance

1 axis present

62.5

µ

s

62,5

µ

s

Minimum

2-axis standard

125

µ

s

125

µ

s

Default value/minimum

2-axis standard

1 axis present

125

µ

s

125

µ

s

Default value/minimum

Notes:

Intermediate values are not permitted (parameterization error).

Exceeding the computing time on the speed controller clock cycle level is not permissible
and will lead to tripping of the drive.

Monitoring cycle

1002

Default value

Lower input limit

Upper input limit

Units

100 000

4 000

100 000

µ

s

Active on

Power On

The interrupt clock cycle is used for high-priority monitoring purposes. Note: The input value
for the clock cycle must be a whole multiple of 4 ms (parameterization error). For the default
value, the monitoring cycle time is 100 ms.

m x 4000

µ

s

m = 1, 2, 3 ... 25

Note:

The interrupts level must not be exceeded. If it is, the drive shuts down.

Configuration STS

1003

Default value

Lower input limit

Upper input limit

Units

0330

0000

FFFF

Hex

Active on

Power On

Caution:

Do not modify this machine data, the default corresponds to the optimum configuration. (For
Siemens service only)

©

Siemens AG 1992 All Rights Reserved 6FC5197- AA50

7–75

SINUMERIK 840C (IA)

Advertising