11.92

12 Functional Descriptions

12.12.5 Influence of the modes on the path dimension function from the PLC

•

Software limit switch (SW-L):
The following effects occur:

SW-L

SW-L

SW-L

SW-L

The path dimension is traversed

The path dimension is not traversed
and aborted

The path dimension is not traversed
and aborted

The path dimension is traversed

1.

2.

3.

4.

•

Transformation
Requirement: Transformation is selected and active.

The following conditions apply:

1.

Fictitious axis as a path dimension axis
The path dimension axis is transformed into a real axis and traversed.

2.

Real axis as a path dimension axis
The real axis is not traversed.
The path dimension function is aborted and a negative acknowledgement is sent to the
PLC.

If the transformation is not selected and not active and the path dimension axis is a
fictitious axis, the path dimension function is aborted.
Delete distance to go has no effect.
In-process measurement is not possible.

•

Coupled motion
Requirement: Coupled motion is selected and active.

The following conditions apply:

1.

Leading axis as the path dimension axis:
The coupled-motion axes traverse with the leading axis.

2.

Coupled-motion axis as the path dimension axis:
Coupled-motion axes are not traversed.
Path dimension is aborted and a negative acknowledgement is sent to the PLC.