Siemens SINUMERIK 840C User Manual

Page 278

Advertising
background image

07.97

6 NC Machine Data (NC MD), NC Setting Data (NC SD)

6.6.1 General MD bits (general bits)

Bit 4

Keyswitch lock for input disable GI

Bit 4=1 Keyswitch setting=0: not possible to program gear interpolation (ELG) via

input display.

Keyswitch setting 0: programming of gear interpolation (ELG) via input
display possible.

Bit 4=0 Keyswitch locking not possible.

Active: immediately

Bit 3

Input of part programs over the operator panel (EDIT, INPUT, CANCEL)

Bit 2

To select dry run feedrate (DRY RUN)

Bit 1

When traversing via handwheel in Automatic mode (DRF function)

Bit 0

Entry of H, S, M, T and D functions in OVERSTORE submode

7

6

5

4

3

2

1

0

Bit No.

NC MD

5007

TO in

diameter

Do not

include tool

wear

Mixed pro-

gramming

G90/91 in

block

Tool basic

dimension

active

No output

of M17

G53 as

@706

Length

compensa-

tion for non-

program-

med axes

Default value:

0000 0100

Active for all bits:

In the next block

Bit 7 Bit 7 = 0

The cutter (tool parameter P1 = 20) is defined as length (P2) and radius
(P4). Consider also NC MD 5008, bit 4.

Bit 7 = 1

The cutter is defined as length and diameter. The cutter radius is always
over radius.

Bit 6

This bit can be used to declare all tool wear data invalid. The tool wear
data (P5 to P7) are thus available for user-specific purposes. A value can
be added to or subtracted from the tool geometry data using the "EDIT"
key.

Bit 5

In a part program, the manner in which programmed values are to be
interpreted, i.e. whether they are to be regarded as absolute (G90) or
incremental (G91) values, always relates to a whole block (up to LF).
Setting bit 5 to 1 makes it possible to define how each separate
programmed value of an axis is to be interpreted as absolute (G90) or
increment (G91) (for further details on interpolation parameters and angles
see NC MD 5003, bits 4 and 5).
Whether he programmed zero offsets G58/G59 are calculated absolutely
or additively also depends on the setting of bit 5.

©

Siemens AG 1992 All Rights Reserved 6FC5197- AA50

6–93

SINUMERIK 840C (IA)

Advertising
This manual is related to the following products: