12 Functional Descriptions

06.93

12.1.2 Functional description

6000

Comp. point 4

Yes/No +/-

Comp. point 3

Yes/No +/-

Comp. point 2

Yes/No +/-

Comp. point 1

Yes/No +/-

Comp. point 5

Yes/No +/-

Comp. point 8

Yes/No +/-

Comp. point 12

Yes/No +/-

Comp. point 996

Yes/No +/-

Comp. point 1000

Yes/No +/-

Comp. point 7

Yes/No +/-

Comp. point 11

Yes/No +/-

Comp. point 6

Yes/No +/-

Comp. point 10

Yes/No +/-

Comp. point 995

Yes/No +/-

Comp. point 999

Yes/No +/-

Comp. point 994

Yes/No +/-

Comp. point 998

Yes/No +/-

Comp. point 993

Yes/No +/-

Comp. point 997

Yes/No +/-

6001

6002

6248

6249

Comp. point 9

Yes/No +/-

7

6

5

4

3

2

1

0

Bit No.

MD No.

-

=

0

+

=

1

No

=

0

Yes

=

1

Since 4 compensation points are available for each machine data, it is specified in the control
that only the point on the far righthand side (bits 0, 1) can be defined as the reference point.

Example

Reference point is to lie on compensation point 793

793 – 1

MD offset = ––––––––––= 198

4

MD offset 198 = MD 6198

Value in MD 316* ... 198

As stated above, the reference point determines the compensation point at which leadscrew
error compensation is activated following reference point approach. No compensation is
allowed at this compensation point!