7 Drive Machine Data (SIMODRIVE Drive MD)

09.95

7.4.3 Diagnosis/service MD (data description - as from SW 3)

Status word 1

11004

Default value

Lower output limit

Upper output limit

Units

0000

FFFF

Hex

Active

after ramp-up

of 611D link

This machine data contains the low-order status bits (bits 0-15) of the cyclical status word at
the interface between SERVO and 611D.

Bit 0

DC link 1 reset

Bit 1

Parking axis setpoint

0 : on
1 : off

Bits 2-4

Assigned to or reserved for internal system functions

Bit 5

Function generator setpoint

0 : on
1 : off

Bit 6

Assigned to or reserved for internal system functions

Bit 7 - SW 4

Ramp-function generator setpoint

0 : on
1 : off

Bit 8

Assigned to or reserved for internal system functions

Bit 9

Bit 10

Bit 11

Ramp-function generator rapid stop setpoint

2nd torque limit setpoint

Speed setpoint smoothing setpoint

0 : off
1 : on

Bits 12-15

Assigned to or reserved for internal system functions

Status word 2

11005

Default value

Lower output limit

Upper output limit

Units

0000

FFFF

Hex

Active

after ramp-up

of 611D link

This machine data contains the high-order status bits (bits 16-31) of the cyclical status word at
the interface between SERVO and 611D.

Bits 0-2

Set of set parameters

0 to 7

Dec

Bit 3

Motor selection setpoint

0 : star
1 : delta

Bit 4

Assigned to or reserved for internal system functions

Bit 5 - SW 4

Bit 6

Bit 7

Bit 8 - SW 4

Bit 9

Motor switchover

Integrator inhibit setpoint

Pulse enable PLC setpoint

Current controller enable setpoint

Speed controller enable NC setpoint

0 : off
1 : on

7–172

©