10 Axis and Spindle Installation

10.2.5 Permissible resolution combinations

Valid combinations of position control resolution and input resolution

Unit

system

Position control

resolution

Input resolution

mm

10

-1

10

-2

10

-3

10

-4

10

-5

inch

10

-1

10

-2

10

-3

10

-4

10

-5

mm

0.5 x 10

-1 [degr.]

xy

-

-

-

-

-

-

-

-

-

mm

0.5 x 10

-2 [mm][degr.]

-

xy

-

-

-

-

-

x

-

-

mm

0.5 x 10

-3 [mm][degr.]

-

-

xy

-

-

-

-

-

x

-

mm

2 x 10

-4 [mm]

-

-

xy

xy

-

-

-

-

-

x

mm

0.5 x 10

-4 [mm][degr.]

-

-

-

xy

-

-

-

-

-

x

mm

0.5 x 10

-5 [degr.]

-

-

-

-

xy

-

-

-

-

-

inch

0.5 x 10

-1 [degr.]

-

-

-

-

-

xy

-

-

-

-

inch

0.5 x 10

-2

[degr.]

-

-

-

-

-

-

xy

-

-

-

inch

0.5 x 10

-3 [inch][degr.]

-

x

-

-

-

-

-

xy

-

-

inch

0.5 x 10

-4 [inch][degr.]

-

x

-

-

-

-

-

-

xy

-

inch

2 x 10

-5 [inch]

-

-

x

-

-

-

-

-

xy

xy

inch

0.5 x 10

-5 [inch][degr.]

-

-

x

-

-

-

-

-

-

xy

xy ...

permissible for both linear and rotary axes

x

...

permissible for linear axes only

...

linear axes and rotary axes illegal

Caution:

The display resolution must use the same unit system (inches - metric - degrees) as the input
resolution.

10.2.6 The influence of resolution on velocity

The input resolution determines not only the path resolution, but also the lowest programmable
velocity. The lowest programmable velocity is always 10 times greater than the path resolution.
For example, if the input resolution is 10

-4

, the lowest programmable velocity is then 10

-3

mm/min. Depending on the unit system used, the feedrate is interpreted either in mm/min or in
inches/min. If one of the interpolating axes is a rotary axis, the corresponding axial
feedrate is interpreted as degrees/min.

When rotational feedrate G95 is used, the feedrate is interpreted in either mm/revolution,
inches/revolution or degrees/revolution.

When the feedrate is rotational, the lowest programmable velocity is identical to the path
resolution (for instance, for an input resolution of 10

-4

, the lowest programmable velocity for

G95 would be 10

-4

mm/revolution).

The limiting value based on the position control resolution can be taken from the table above.
At no time may the limiting values be exceeded.