Siemens SINUMERIK 840C User Manual

Page 568

Advertising
background image

04.96

7 Drive Machine Data (SIMODRIVE Drive MD)

7.3.2 Drive MD (data description)

Value display monitor

1657

Default value

Lower output limit

Upper output limit

Units

0000 0000

0000 0000

FFFF FFFF

Hex

Active

at once

Output of monitoring function display value. This machine data displays the content of the
address resulting from the segment (MD 1655) and the offset (MD 1656).

Value input monitor

1658

Default value

Lower input limit

Upper input limit

Units

0000 0000

0000 0000

FFFF FFFF

Hex

Active

at once

A 24-bit value can be entered in this machine data. The value is written in the monitoring
function to the address specified by the segment (MD 1655) and the offset (MD 1656). The
value is not written until machine data "Value acceptance monitor" (MD 1659) has been set
to 1.

Caution:

This machine data is relevant only for Siemens-internal purposes and must not be altered.

Value acceptance monitor

1659

Default value

Lower input limit

Upper input limit

Units

0

0

1

Active

at once

This machine data writes the value (MD 1658) to the addressed memory location (MD 1655,
MD 1656) if the value "1" has been entered to initiate the write operation. On completion of
the write operation, the machine data is automatically reset to "0".

Caution:

This machine data is relevant only for Siemens-internal purposes and must not be altered.

Motor frequency V/f mode (SW 4.4 only)

1660

Default value

Lower input limit

Upper input limit

Units

1.0

-10000.0

10000.0

Hz

Active

at once

Input of a setpoint frequency (electrical) for the drive in voltage-controlled V/f mode. The +
or – sign corresponds to the appropriate direction of rotation of the motor.

Note:

This machine data is only used for diagnostics and may only be used or applied by trained
service personnel.

©

Siemens AG 1992 All Rights Reserved 6FC5197- AA50

7–153

SINUMERIK 840C (IA)

Advertising
This manual is related to the following products: