Siemens SINUMERIK 840C User Manual

Page 1041

Advertising
background image

12 Functional Descriptions

07.97

12.25.4 Memory configuration on control power-up

If a module with 486 CPU is installed and digital drives are connected, the MD mentioned
above must be set to "1".

Loading the drive software as from SW 6

General notes:

Up to SW 5 the drive software (MSD and FDD) is loaded from the MMC hard disk into the
NCK user memory in its entirety while the control powers up and is then transferred to the
drive when the drive powers up. For this, the use must make 192 Kbytes of NCK memory
available per package.

As from SW 6 this memory is not large enough for the drive software. There are two ways of
loading the drive software.

1. Increase the size of the NCK user memory for MSD/FDD
Advantage:

Fast loading of the drive software

Disadvantage:

Larger user memory requirement

2. Retroload the drive software from the hard disk in packages
Advantage:

No additional user memory requirement

Disadvantage:

Longer power-up times

The available memory is set via NC-MD 60016. The drive software memory requirement can
be increased from 288 Kbytes to 384 Kbytes for more recent software versions. If less
memory is made available than is needed for the drive software, the missing software is
retroloaded from the hard disk, thus increasing the time which the control takes to power up.

No.

Number of drive

packages

Memory required

Corr. to

MD 60014

Power-up time

increased

1

1 (MSD or FDD)

192 K

2

yes

2

1 (MSD or FDD)

288 K

3

no

3

2 (MSD or FDD)

192 K

2

yes, considerably

4

2 (MSD or FDD)

384 K

4

yes

5

2 (MSD or FDD)

576 K

6

no

Lines 1 and 4 give settings that are compatible with 840C SW 3 and 5. They result in a (slight)
increase in the power-up time without requiring more user memory.

Lines 2 and 5 show the recommended settings for 840C SW 6. Here, more user memory is
required but power-up is quickest with these settings.

Line 3 shows a setting that requires less user memory than SW 3-5. However, here the power-
up time of the control has increased considerably.

12–266

© Siemens AG 1992 All Rights Reserved 6FC5197- AA50

SINUMERIK 840C (IA)