Siemens SINUMERIK 840C User Manual

Page 261

Advertising
background image

6 NC Machine Data (NC MD), NC Setting Data (NC SD)

09.95

6.5 Spindle-specific MD (spindle data)

Structure of MD 460*

Digit No.

7

6

5

4

3

2

1

0

0

1

0

4

0

0

0

0

Example showing the
structure of a value in
MD 460*

Servo loop

module

number

No. of

servo loop

connection

Always 0
for analog
module

Meaning of the individual terms

Digit No. 7, 6

The servo loop module number is the number of the module on the
servo local bus. The modules are numbered from left to right in ascending
order. The far left module has the number 1.

Permissible values:

00 to 5

Digit No. 5, 4

The number of the servo loop connection determines the number of
the output on the selected HMS or SPC module.

Permissible values:

04 to 06 for SPC servo loop modules
04 to 12 for HMS servo loop modules

Note

The value ”00 00 00 00” for MD 460* is permissible only if the spindle does not exist for
the control (MD 521*, bit 7=0).

Setpoint output (digital) (as from SW 3)

460*

Default value

Lower input limit

Upper input limit

Units

0

0

15001000 (up to SW 4)

30001000 (as from SW 5)

Active on

Power On

Exact description see MD 384*.

Note

See Section 5, Machine Data Dialog, for the servo loop assignment.

Setpoint to digital drive

4600,2-3

Default value

Lower input limit

Upper input limit

Units

0

Active

SP/HMS setpoint output No.

4600,4-5

Default value

Lower input limit

Upper input limit

Units

0

0

12

Active

Drive/servo loop module No.

4600,6-7

Default value

Lower input limit

Upper input limit

Units

0

0

30

Active

6–76

©

Siemens AG 1992 All Rights Reserved 6FC5197- AA50

SINUMERIK 840C (IA)

Advertising