Siemens SINUMERIK 840C User Manual

Page 468

Advertising
background image

12.93

7 Drive Machine Data (SIMODRIVE Drive MD)

7.2.2 FDD MD (data description - SW 3)

Power section code

1106

Default value

Lower input limit

Upper input limit

Units

0000

0000

00FF

Hex

Active on

Power On

When the power section order number (machine-readable product designation for Siemens
power sections) is input during initial start-up, it is converted to a code number as an MMC
function (the user need not enter a code number). The following power section data are
automatically transferred from an internal power section table through the input of the code
number:

Limit current transistor (MD 1107)

maximum thermal current of the power section (MD 1108)

Format of power section code number:

Power section type

0

1

MSD

FDD

2

3

4

5

6

7

8

9

A

B

C

D

E

F

Not assigned

Amperage

0

1

No power section specified

3 / 6 A

2

3

4

5

6

7

8

9

A

B

C

D

E

F

5 / 10 A

Not assigned

9 / 18 A

Not assigned

18 / 36 A

28 / 56 A

Not assigned

56 / 112 A

70 / 140 A

Not assigned

Limit current transistor

1107

Default value

Lower input limit

Upper input limit

Units

200

1

500

A

Active on

Power On

Input of maximum permissible current of power section. This input makes allowance for the
rating of the transistors minus thermal reserves (approximately 20 %). The maximum current
must be set as a peak value independently of the pulse frequency. This machine data is
automatically parameterized for Siemens power sections by the machine data "Power section
code" (MB 1106).

Caution:

This data serves as the basis for normalizing the current actual value sensor and must not be
changed
by the user after automatic presetting of its values.

©

Siemens AG 1992 All Rights Reserved 6FC5197- AA50

7–53

SINUMERIK 840C (IA)

Advertising