Siemens SINUMERIK 840C User Manual

Page 508

Advertising
background image

04.96

7 Drive Machine Data (SIMODRIVE Drive MD)

7.3.2 Drive MD (data description)

cos

power factor

1129

Default value

Lower input limit

Upper input limit

Units

0.8

0.0

1.0

Active on

Power On

cos

is required for the calculation of the equivalent circuit diagrams from the data on the

rating plate.

Note:

This machine data only applies to main spindle drives.

Motor rated power

1130

Default value

Lower input limit

Upper input limit

Units

0.0

0.0

1 500.0

kW

Active on

Power On

Input of motor rated power as specified on the motor data sheet (non-Siemens motor) or
automatic parameterization using machine data "Motor code number" (MD 96).

Note:

This data is relevant only for MSD drives.

Motor rated voltage

1132

Default value

Lower input limit

Upper input limit

Units

380.0

0.0

5 000.0

V

Active on

Power On

Input of motor rated voltage as specified on the motor data sheet (non-Siemens motor) or
automatic parameterization using machine data "Motor code number" (MD 1102).

Motor rated frequency

1134

Default value

Lower input limit

Upper input limit

Units

50.0

0.0

3 000.0

Hz

Active on

Power On

Input of motor rated frequency as specified on the motor data sheet (non-Siemens motor) or
automatic parameterization using machine data "Motor code number" (MD 1102).

Note:

This data is relevant only for MSD drives.

©