Siemens SINUMERIK 840C User Manual

Page 949

Advertising
background image

12 Functional Descriptions

10.94

12.18.15 Gearbox interpolation status data

12.18.15

Gearbox interpolation status data

In the SINUMERIK 840C control system, the currently valid configuration and status data of the
active and inactive GI groupings are stored in the so-called gearbox interpolation (GI) status
data. A memory area is reserved for each axis and spindle because every axis/spindle could
be a following axis/spindle. The memory area is buffered so that the gearbox configurations are
not lost after power off. The data are read after power on and the link activated during ramp-up
(used for gantry axes) provided that the enabling command is present (NC MD 1844*/525*
LINK ON after POWER ON). The GI status data can be erased in general reset mode.

These data lists can be read in or out as %GIA data via the RS 232 C (V.24) interface. Data
can be read in only in start-up mode and read out only when the SINUMERIK is in the reset
state.

12.18.15.1 Format of data list (SW 3)

Type 0
Axis 1

GIA 0...5

GIA 100...106

GIA 200...206

GIA 300...306

GIA 400...406

GIA 500...506

Type 29
Axis 30

GIA 0..5

GIA 100...106

GIA 200...206

GIA 300...306

GIA 400...406

GIA 500...506

Type 40
Spindle 1

GIA 0..5

GIA 100...106

GIA 200...206

GIA 300...306

GIA 400...406

GIA 500...506

Type 45
Spindle 6

GIA 0..5

GIA 100...106

GIA 200...206

GIA 300...306

GIA 400...406

GIA 500...506

FD

LD1

LD2

LD3

LD4

LD5

FD

LD1

LD2

LD3

LD4

LD5

FD

LD1

LD2

LD3

LD4

LD5

FD

LD1

LD2

LD3

LD4

LD5

. . .

. . .

Format of data list (SW 4)

Type 0
Axis 1

GIA 0...5.9

GIA 100...109

GIA 200...209

GIA 300...309

GIA 400...409

GIA 500...509

Type 29
Axis 30

GIA 0..5.9

GIA 100...109

GIA 200...209

GIA 300...309

GIA 400...409

GIA 500...509

Type 40
Spindle 1

GIA 0..5.9

GIA 100...109

GIA 200...209

GIA 300...309

GIA 400...409

GIA 500...509

Type 45
Spindle 6

GIA 0..5.9

GIA 100...109

GIA 200...209

GIA 300...309

GIA 400...409

GIA 500...509

FD

LD1

LD2

LD3

LD4

LD5

FD

LD1

LD2

LD3

LD4

LD5

FD

LD1

LD2

LD3

LD4

LD5

FD

LD1

LD2

LD3

LD4

LD5

. . .

. . .

Note:

This data list is merely intended as a back-up file for servicing purposes and must not
therefore be changed by the user.