7 Drive Machine Data (SIMODRIVE Drive MD)

7.3.2 Drive MD (data description)

3rd filter

Bit 2

0

1

Low-pass (see MD 1206/1207)

Band-stop (see MD 1216/1217/1218)

4th filter

Bit 3

0

1

Low-pass (see MD 1208/1209)

Band-stop (see MD 1219/1220/1221)

Note:

Before the filter type is configured, the appropriate filter machine data must be input.

Natural frequency current setpoint filter 1

1202

Default value

Lower input limit

Upper input limit

Units

2 000.0

0.0

8 000.0

Hz

Active

at once

Input of natural frequency for current setpoint filter 1 (PT2 low-pass). An entry of < 10 Hz as
the natural frequency of the low-pass filter initializes the filter as a proportional element with a
gain of 1 independently of the associated damping. The filter is activated via machine data
MD 1200 (No. current setpoint filters) and MD 1201 (Type current setpoint filter).

Notes:

Current setpoint filter 1 is preset to the current controller sampling time MD 1000 =
125

µ

s for damping of the encoder torsional natural frequency.

For a current controller sampling time of MD 1000 = 62.5

µ

s, we recommend that the

natural frequency be changed to f

o

= 3000 Hz to achieve an optimum dynamic response

of the controller.

Damping current setpoint filter 1

1203

Default value

Lower input limit

Upper input limit

Units

0.7

0.05

5.0

Active

at once

Input of damping for current setpoint filter 1 (PT2 low-pass). The filter is activated via machine
data MD 1200 (No. current setpoint filters) and MD 1201 (Type current setpoint filter).
0.7 ˆ

= 70%

1 ˆ

= 100%

Note:

Current setpoint filter 1 is preset to the current controller sampling time MD 1000 =
125

µ

s for damping of the encoder torsional natural frequency.

Natural frequency current setpoint filter 2

1204

Default value

Lower input limit

Upper input limit

Units

0.0

0.0

8 000.0

Hz

Active

at once

Input of natural frequency for current setpoint filter 2 (PT2 low-pass). An entry of < 10 Hz as
the natural frequency of the low-pass filter initializes the filter as a proportional element with a
gain of 1 independently of the associated damping. The filter is activated via machine data
MD 1200 (No. current setpoint filters) and MD 1201 (Type current setpoint filter).

©

Siemens AG 1992 All Rights Reserved 6FC5197- AA50