8 PLC Machine Data (PLC MD)

09.95

8.2 PLC MD for the operating system (system data)

No. of function numbers

19

Default value

Lower input limit

Upper input limit

Units

3

0

10

DB 60

DW 19

Number of function numbers for a UI kernel sequence initiation.

Input values:

0

=

UI kernel sequence initiation not allowed in this PLC

1...10 (max.)

=

UI kernel sequence initiation allowed.
The input value specifies the number of function numbers,
beginning with MD DB60, DW20, for a UI kernel sequence
initiation.

3

=

Default value

See Computer Link.

Function no. for kernel sequence initiation

20-29

Default value

Lower input limit

Upper input limit

Units

see table

0

255

DB 60

DW 20-29

Default value

MD

Value

20

25

21

26

22

30

23

.

.

.

29

0

.

.

.

0

See Computer Link.

Spare

31

Default value

Lower input limit

Upper input limit

Units

- 1

- 1

127

DB 60

DW 31

No. of interrupt byte on interface PLC/PLC 135 WD

30

DB 60

DW 30

This tells the PLC operating system the number of the interrupt byte to be processed on the
interface module.

Enter - 1 if no byte is to be processed. If a high-speed input is to be processed, it must be
interfaced over the IF PLC module's X141 connector. There can be as many as eight inputs.
The relevant input byte is specified in this MD.

8–6

© Siemens AG 1992 All Rights Reserved 6FC5197- AA50