6 loading via v24 interface or fd-e2 – Siemens SINUMERIK 840C User Manual

Page 768

Advertising
background image

01.99

11 Data Backup/CPU Replacement

11.1.6 Loading via V24 interface or FD-E2

11.1.6 Loading via V24 interface or FD-E2

Example: Replacement of MMC CPU

MMC software is loaded (same software version)

Enter password for Diagnosis operating area

Set date/time in Diagnosis operating area

Connect external device

Attention: FD-E2 requires booting from MMC

Select Services operating area/device

Load user data via V24 interface or floppy

via Data input/Input start

PLC MD, ”Load from disk” via Diagnosis/

Startup/Machine data/File function

Carry out a PLC restart via PG

or Diagnosis/General reset mode

If required load data from disk to NCK

© Siemens AG 1992 All Rights Reserved 6FC5197- AA50