Siemens SINUMERIK 840C User Manual

Page 1133

Advertising
background image

12 Functional Descriptions

01.99

12.35 Uninterruptible power supply (UPS) (as from SW 6.3) (Express shutdown)

Example: PLC program for the initiation of an ”Express shutdown”

A

DB255

User DB

L

KF 10

Package length

T

DW 10

L

KH 0201

Sender (PLC)

T

DW 11

L

KH 0319

Receiver (MBX)

T

DW 12

L

KH 001

Task data structure

T

DW 13

L

KH 5F02

Task number

T

DW 14

L

KH 2F04

I code

T

DW 15

L

KH 0090

Control flag

T

DW 16

BA

FX73
OEM-SEND

DBTY

KC

DB

DBNR

KF

255

DWNR

KF

10

QTTG

KF

192

.
.
.

Scanning of the OEM information bit (PLC-MD 137).
Only once bit ”0” or ”1” has been set, then data
(acknowledgement) are present in the mailbox.
In this dependency the FX74 is called up.

BA

FX74
OEM-EMPF

DBTY

KC

DB

DBNR

KF

255

DWNR

KF

20

OEMN

KF

0

QTTG

KF

195

Data received:
(as acknowledgement, ”Express shutdown” implemented, the I code is returned)

DB 255

DW20

KH = 0004

Package length

DW21

KH = 0319

Sender (MBX)

DW22

KH = 0201

Receiver (PLC)

DW23

KH = 0001

Task data structure

DW24

KH = 0000

Task number

DW25

KH = 2F04

I code

DW26

KH = 0094

Control flag

12–358

© Siemens AG 1992 All Rights Reserved 6FC5197- AA50

SINUMERIK 840C (IA)

Advertising