Siemens SINUMERIK 840C User Manual

Page 316

Advertising
background image

09.95

6 NC Machine Data (NC MD), NC Setting Data (NC SD)

6.6.2 Spindle-specific MD bits (spindle bits)

Following spindle-specific machine data bits

7

6

5

4

3

2

1

0

Bit No.

NC MD

525*

Test bit

compensa-

tory

controller

Position

overwrite

permissible

Coupling

factor

switchover

permissible

Reconfig.

permissible

Spindle can

be FS

The following bits only apply to following spindles and are active after Power on.

Bit 5

Test bit compensatory controller

Bit 5=1 Compensatory controller test mode switched on

Bit 5=0 Compensatory controller test mode not switched on.

Bit 3

Position overwrite permissible

Bit 3=1 Overwriting positions enabled

Bit 3=0 The synchronous positions (or switching positions) entered for the leading

axes/spindles must not be overwritten. I.e., synchronization must always start
with the same positions.

Bit 2

Coupling factor switchover permissible

Bit 2=1 Switching over the coupling factor is permitted (with G402, G403 commands

or via input display)

Bit 2=0 Switchover not permitted.

Bit 1

Reconfiguration permissible

Bit 1=1 Reconfiguration is permissible (with G401 command or via input display)

Bit 1=0 Reconfiguration not permissible

Bit 0

Spindle can be following spindle

Bit 0=1 Spindle can be following spindle

Bit 0=0 Spindle must not be a following spindle

©