Siemens SINUMERIK 840C User Manual

Page 452

Advertising
background image

12.93

7 Drive Machine Data (SIMODRIVE Drive MD)

7.1.2 MSD MD (data description - SW 3)

Control word message

247

Default value

Lower input limit

Upper input limit

Units

0000

0000

FFFF

Hex

Active

at once

By setting bits 0 to 5, it is possible to invert the function of the appropriate messages (MD 241
to MD 246). In bits 8 and 9, it is possible to choose between sign-specific or absolute-value-
based interrogation of the memory address limit values (MD 185, MD 190).

Value table:

Bit 0

Programmable message 1 inverted

0001H

Bit 1

Programmable message 2 inverted

0002H

Bit 2

Programmable message 3 inverted

0004H

Bit 3

Programmable message 4 inverted

0008H

Bit 4

Programmable message 5 inverted

0010H

Bit 5

Programmable message 6 inverted

0020H

Bits 6-7

Not assigned

Bit 8

Sign evaluation monitoring 1

0040H

Bit 9

Sign evaluation monitoring 2

0080H

Bits

10-15 Not assigned

Display of active functions 1

254

Default value

Lower output limit

Upper output limit

Units

Hex

Active

at once

Display of low word in drive control word.

Value table:

Bit 0

Bit 1

Bit 2-6

Bit 7

Bit 8

Bit 9

Bit 10

Bit 11

Bit 12-15

ZK1 reset

Parking axis

Not assigned

Ramp-function generator active

Not assigned

Ramp-function generator rapid stop

2nd torque limit

Speed setpoint smoothing

Not assigned

0: Not active
1: Active

©

Siemens AG 1992 All Rights Reserved 6FC5197- AA50

7–37