10.94

7 Drive Machine Data (SIMODRIVE Drive MD)

7.4.3 Diagnosis/service MD (data description - as from SW 3)

Capacity utilization (as from SW 4)

11009

Default value

Lower output limit

Upper output limit

Units

0000

7FFF

Hex

Active

at once

This machine data specifies the capacity utilization of the digital drive as a percentage
(0 ... 7FFF H ˆ

= 0 ... 100%).

Torque setpoint (as from SW 4)

11010

Default value

Lower output limit

Upper output limit

Units

-32 768

32 767

Active

at once

This machine data specifies the torque setpoint of the digital drive as a percentage
(-32768 ... 32767 ˆ

= -200% ... 200%). The torque corresponding to 100 % (internal notation

4000 H) is stored in machine data "Scaling torque setpoint interface" (MD 1725).

Active power (as from SW 4)

11011

Default value

Lower output limit

Upper output limit

Units

-327.68

327.67

kW

Active

at once

This machine data specifies the active power of the digital drive.

Current actual value (as from SW 4)

11012

Default value

Lower output limit

Upper output limit

Units

-32 768

32 767

Active

at once

This machine data specifies the current actual value of the digital drive as a percentage
(-32768 ... 32767 ˆ

= -200% ... 200%). The limit current corresponding to 100 % (internal

notation 4000 H) is stored in the machine data "Transistor limit current power section" (MD
1107).

Speed actual value (as from SW 4)

11013

Default value

Lower output limit

Upper output limit

Units

-200

200

%

Active

at once

This machine data specifies the current actual value of the digital drive. The actual speed
value corresponding to 100 % (internal notation 4000 H) is stored in the machine data "Speed
for max. motor operational speed" (MD 1401).

©

Siemens AG 1992 All Rights Reserved 6FC5197- AA50