Siemens SINUMERIK 840C User Manual

Page 517

Advertising
background image

7 Drive Machine Data (SIMODRIVE Drive MD)

09.95

7.3.2 Drive MD (data description)

Specified: Blocking frequency 1 kHz, 500 Hz bandwidth and 250 Hz bandwidth numerator
(damping)

1

10

Log

1k

10 kHz

20.0

0.0

dB

-60.0

100

-5.0

Blocking frequency

1

10

Log

1k

10 kHz

180

Deg

-180

100

Type current setpoint filter

1201

Default value

Lower input limit

Upper input limit

Units

Low-pass

Low-pass

Band-stop

Active

at once

Input of configuration of 4 current setpoint filters. Band-stop and low-pass filters are available.
The adjustable filter parameters are entered in the appropriate machine data.

Value table:

1st filter

Bit 0

0

1

Low-pass (see MD 1202/1203)

Band-stop (see MD 1210/1211/1212)

2nd filter

Bit 1

0

1

Low-pass (see MD 1204/1205)

Band-stop (see MD 1213/1214/1215)

7–102

©

Siemens AG 1992 All Rights Reserved 6FC5197- AA50

SINUMERIK 840C (IA)

Advertising
This manual is related to the following products: