6 NC Machine Data (NC MD), NC Setting Data (NC SD)

6.7 Axis-specific MD 2 (axial data 2)

Time constant parallel model 2nd - 8th parameter set

(as from SW 4)

1708*-

1732*

Default value

Lower input limit

Upper input limit

Units

6 000

0

16 000

0.01 ms

Active on

RESET

These MD have the same meaning as MD 1432*, see also ”Functional Descriptions:
Parameter set switchover”.These machine data are only active with gearbox interpolation.

Alarm limit velocity 1st - 8th parameter set

(as from SW 4)

1736*-

1764*

Default value

Lower input limit

Upper input limit

Units

11 000

1

99 999 999

10 000 units/s

2

Active on
NC Stop

Meaning: Limitation of max. velocity for following axis. These machine data are only active with
gearbox interpolation.

Note:

For parameter grouping see under ”Functional Descriptions: Parameter set switchover”.

Alarm limit acceleration 1st - 8th parameter set

(as from SW 4)

1768*-

1796*

Default value

Lower input limit

Upper input limit

Units

55

0

16 000

10 000 units/s

2

Active on
NC Stop

Meaning: Limitation of max. acceleration for following axis. These machine data are only active
with gearbox interpolation.

Note:

For parameter grouping see under ”Functional descriptions: Parameter set switchover”.

©

Siemens AG 1992 All Rights Reserved 6FC5197- AA50