6 NC Machine Data (NC MD), NC Setting Data (NC SD)

09.95

6.7.1 Axis-specific MD 2 (axial data 2)

Exact stop limit fine 2nd - 8th parameter set

1568*-

1592*

Default value

Lower input limit

Upper input limit

Units

10

+0

16 000

units (MS)

10

+0

99 999 999 (as from

SW 4.4)

units (MS)

Active on
NC Stop

These MD have the same meaning as MD 208*, see also ”Functional Descriptions: Parameter
set switchover”.

Zero speed monitoring 2nd - 8th parameter set

1596*-

1620*

Default value

Lower input limit

Upper input limit

Units

100

0

16 000

units (MS)

100

0

99 999 999 (as from

SW 4.4)

units (MS)

Active on
NC Stop

These MD have the same meaning as MD 212*, see also ”Functional Descriptions: Parameter
set switchover”.

P component compensatory controller 2nd - 8th parameter

set (as from SW 4)

1624*-

1648*

Default value

Lower input limit

Upper input limit

Units

0

0

16 000

1

Active on

RESET

These MD have the same meaning as MD 1420*, see also ”Functional Descriptions:
Parameter set switchover”.

I component compensatory controller 2nd - 8th parameter

set (as from SW 4)

1652*-

1676*

Default value

Lower input limit

Upper input limit

Units

0

0

16 000

1

Active on

RESET

These MD have the same meaning as MD 1424*, see also ”Functional Descriptions:
Parameter set switchover”.

D component compensatory controller 2nd - 8th parameter

set (as from SW 4)

1680*-

1704*

Default value

Lower input limit

Upper input limit

Units

0

0

16 000

1

Active on

RESET

These MD have the same meaning as MD 1428*, see also ”Functional Descriptions:
Parameter set switchover”.