Siemens SINUMERIK 840C User Manual

Page 513

Advertising
background image

7 Drive Machine Data (SIMODRIVE Drive MD)

07.97

7.3.2 Drive MD (data description)

P gain flux controller

1150

Default value

Lower input limit

Upper input limit

Units

400.0

0.0

100 000.0

A/Vs

Active

at once

Input of the proportional gain of the flux controller or automatic paramterization (initialization)
through the operator action Calculate controller data.

Note:

This data is relevant only for MSD drives.

Integral-action time flux controller

1151

Default value

Lower input limit

Upper input limit

Units

10.0

0.0

500.0

ms

Active

at once

Input of the control variable integral-action time flux controller or automatic paramterization by
the operator action Calculate controller data.

Speed for start of flux detection

1160

Default value

Lower input limit

Upper input limit

Units

1 500.0

200.0

50 000.0

rev/min

Active

at once

Above the set speed flux detection is active, below the set speed a flux model is used. The
parameter default is set for "Calculate controller data" and should not be changed.

Note:

This machine data only applies to main spindle drives.

DC link fixed voltage

1161

Default value

Lower input limit

Upper input limit

Units

600

0 (as from SW 6)

0

700

V

Active

at once

By specifying a DC link fixed voltage > 0V DSP internal DC link measurement is deactived
here, i.e. MD 1701 (between loop voltage display) is inactive (display: "

*

").

The given voltage is included instead of the measurement in:

DC link adaptation

Flux acquisition (MSD)

The permissibility of an activation of the DC link measurement (MD 1161=0) is monitored in
accordance with hardware configuration 5 (error message 300765).

Caution:

It is not possible to activate emergency retractive functions with deactivated DC link
measurement (MD 1161 > 0) (error message 300764).

7–98

©

Siemens AG 1992 All Rights Reserved 6FC5197- AA50

SINUMERIK 840C (IA)

Advertising