Siemens SINUMERIK 840C User Manual

Page 1116

Advertising
background image

08.96

12 Functional Descriptions

12.33.3 Current setpoint filter

Filter in the case of resonance at and above the controller stability limit

Low-pass

With resonance bundle

Distribution of resonance phenomena (dependent on traversing direction, speed)

Low-pass as current setpoint filter

A low-pass filter is the better solution in cases where a peak occurs in the amplitude response
that is not linked to a fixed frequency, but wanders under different conditions. With a low-pass
filter, the signal above the entered natural frequency is damped. Reduced damping results in
less phase rotation below the natural frequency and thus to a greater phase margin.

Amplitude response

Magnitude
[dB]

log f [Hz]

10

2

10

3

10

3
0

-3

-10

-20

-30

Phase response

Phase
angle

log f [Hz]

10

2

10

3

180

90

0

-90

-180

0.2

1.0

0.5

1.0

0.5

0.2

Fig. 12-4

Low-pass behaviour at natural frequency of 1000 Hz
and variation in damping of 0.2, 0.5 and 1.0

© Siemens AG 1992 All Rights Reserved 6FC5197- AA50