Siemens SINUMERIK 840C User Manual

Page 539

Advertising
background image

7 Drive Machine Data (SIMODRIVE Drive MD)

08.96

7.3.2 Drive MD (data description)

Torque threshold characteristic for the message M

d

< M

dx

.

Presently valid
torque limit value

Threshold
torque

M

breakd.

P

limit

Power limitation

M

limit

M

n

1/n

1/n

2

The "M

d

< M

dx

" message is locked in the active state as long as the "Power-up procedure

competed" message is not active. If the latter message is active, then the delay time set in
MD 1429 must also elapse before the "M

d

< M

dx

" message is deactivated.

Delay time M

d

< M

dx

message

1429

Default value

Lower input limit

Upper input limit

Units

800.0

0.0

1 000.0

ms

Active

at once

Input of delay time which must elapse before the "M

d

< M

dx

" message can be deactivated

after the "Power-up procedure completed" message. The "M

d

< M

dx

" message remains

locked in the active position as long as "Power-up procedure completed" is not active or the
delay time has not yet elapsed.

Number of speed setpoint filters

1500

Default value

Lower input limit

Upper input limit

Units

0

0

2

Active

at once

Input to specify number of speed setpoint filters. A selection of band-stop and low-pass filters
(PT2/PT1) are available which can be set via machine data MD 1501 "Type of speed setpoint
filter".

Selection of number of filters:

0

No speed setpoint filter active

1

Filter 1 active

2

Filters 1 and 2 active

7–124

©

Siemens AG 1992 All Rights Reserved 6FC5197- AA50

SINUMERIK 840C (IA)

Advertising
This manual is related to the following products: