6 NC Machine Data (NC MD), NC Setting Data (NC SD)

09.95

6.4 Axis-specific MD 1 (axial data 1)

Time constant symmetrizing filter

392*

Default value

Lower input limit

Upper input limit

Units

0

+0

1 000

0.1 ms

Active

In order to avoid axis overshooting when working with feedforward control, the set part position
is fed to the position controller with a time delay. This delay is set with this machine data.

Input value:

= 0

Static feedforward control (e.g. for AC drives with a rise time < position control
sampling interval)

0

Dynamic feedforward control (for axes with a rise time > position control sampling
interval)

Note:

Normal:

1

/

2

rise time of drive

As from SW 4, for 8 parameter sets

Absolute offset

396*

Default value

Lower input limit

Upper input limit

Units

0

- 99 999 999

99 999 999

units (IS)

Active on

Power On

Active after POWER ON

The offset is calculated automatically on reference point approach (SIPOS, ENDAT) or can be
entered manually without a reference point approach (SIPOS, ENDAT, distance coding).

NC machine data bits 1808* bits 0 to 4 must be taken into consideration. On reference point
approach with distance coded reference marks, the offset between the machine zero and the
linear scale is entered as the offset. (See Section entitled ”Axis (Analog) and Spindle
Installation” for calculation)

Note:

Observe MD 1808, bit 1 ”Value range extension of absolute offset” as from SW 5.

6–64

©

Siemens AG 1992 All Rights Reserved 6FC5197- AA50

SINUMERIK 840C (IA)