7 Drive Machine Data (SIMODRIVE Drive MD)
7.1.2 MSD MD (data description - SW 3)
Phase current
controller gain
n
4 x gain set
in MD 278
MD 278
MD 337
MD 292
Selection adaption speed controller motor 2
293
Default value
Lower input limit
Upper input limit
Units
0
0
7
–
Active
at once
Input of activation point for speed controller adaption. The diagram shows how the individual
machine data influence the speed characteristic (see MD 203 for diagram).
0:
No speed controller adaption
1:
No function assigned at present
2:
Speed controller adaption activated
3:
No function assigned at present
Note:
The speed controller adaption function is available only for operation in gear stage 1.
Current with I/f control
311
Default value
Lower input limit
Upper input limit
Units
40.0
0.0
100.0
%
Active
at once
The I/f control is used to assist diagnosis in the event of encoder faults. The current amplitude
can be specified in this machine data.
Frequency for I/f control
312
Default value
Lower input limit
Upper input limit
Units
0
-800.0
800.0
Hz
Active
at once
The I/f control is used to assist diagnosis in the event of encoder faults. The frequency can be
specified in this machine data. The sign determines the direction of rotation.
©