7 Drive Machine Data (SIMODRIVE Drive MD)

7.1.2 MSD MD (data description - SW 3)

Phase current
controller gain

n

4 x gain set
in MD 278

MD 278

MD 337

MD 292

Selection adaption speed controller motor 2

293

Default value

Lower input limit

Upper input limit

Units

0

0

7

Active

at once

Input of activation point for speed controller adaption. The diagram shows how the individual
machine data influence the speed characteristic (see MD 203 for diagram).

0:

No speed controller adaption

1:

No function assigned at present

2:

Speed controller adaption activated

3:

No function assigned at present

Note:

The speed controller adaption function is available only for operation in gear stage 1.

Current with I/f control

311

Default value

Lower input limit

Upper input limit

Units

40.0

0.0

100.0

%

Active

at once

The I/f control is used to assist diagnosis in the event of encoder faults. The current amplitude
can be specified in this machine data.

Frequency for I/f control

312

Default value

Lower input limit

Upper input limit

Units

0

-800.0

800.0

Hz

Active

at once

The I/f control is used to assist diagnosis in the event of encoder faults. The frequency can be
specified in this machine data. The sign determines the direction of rotation.

©

Siemens AG 1992 All Rights Reserved 6FC5197- AA50

7–45

SINUMERIK 840C (IA)