7 Drive Machine Data (SIMODRIVE Drive MD)

09.95

7.3.2 Drive MD (data description)

Damping current setpoint filter 2

1205

Default value

Lower input limit

Upper input limit

Units

1.0

0.05

5.0

Active

at once

Input of damping for current setpoint filter 2 (PT2 low-pass). The filter is activated via machine
data MD 1200 (No. current setpoint filters) and MD 1201 (Type current setpoint filter).

Natural frequency current setpoint filter 3

1206

Default value

Lower input limit

Upper input limit

Units

0.0

0.0

8 000.0

Hz

Active

at once

Input of natural frequency for current setpoint filter 3 (PT2 low-pass). An entry of < 10 Hz as
the natural frequency of the low-pass filter initializes the filter as a proportional element with a
gain of 1 independently of the associated damping. The filter is activated via machine data MD
1200 (No. current setpoint filters) and MD 1201 (Type current setpoint filter).

Damping current setpoint filter 3

1207

Default value

Lower input limit

Upper input limit

Units

1.0

0.05

5.0

Active

at once

Input of damping for current setpoint filter 3 (PT2 low-pass). The filter is activated via machine
data MD 1200 (No. current setpoint filters) and MD 1201 (Type current setpoint filter).

Natural frequency current setpoint filter 4

1208

Default value

Lower input limit

Upper input limit

Units

0.0

0.0

8 000.0

Hz

Active

at once

Input of natural frequency for current setpoint filter 4 (PT2 low-pass). An entry of < 10 Hz as
the natural frequency of the low-pass filter initializes the filter as a proportional element with a
gain of 1 independently of the associated damping. The filter is activated via machine data MD
1200 (No. current setpoint filters) and MD 1201 (Type current setpoint filter).

7–104

©

Siemens AG 1992 All Rights Reserved 6FC5197- AA50

SINUMERIK 840C (IA)