Siemens SINUMERIK 840C User Manual

Page 554

Advertising
background image

09.95

7 Drive Machine Data (SIMODRIVE Drive MD)

7.3.2 Drive MD (data description)

Config. shutdown react. RESET alarms

1613

Default value

Lower input limit

Upper input limit

Units

0100/FFFF

0000

FFFF

Hex

Active

at once

Input bit field for switching over the appropriate 611D reset alarm. It is possible to select one of
two shutdown reactions, i.e. pulse disable (bit = 1) or controller disable (bit = 0 ˆ

= nset = 0

ˆ

= generator-mode braking), i.e. when the pulse disable reaction is selected, the controller

disable reaction is deactivated. The default setting is dependent on the motor type (FDD =
0100, MSD = FFFF) and is parameterized by the drive configuration during start-up.

Note:

The MSD default setting (FFFF) must be selected when the FDD H option is used.
611D messages can be switched to reset alarms via MD 1012 bit 4.

Caution:

The alarms may be deactivated or concealed through machine data MD 1601 - Concealable
alarms (reset), i.e. they may be inactive.

Value table:

Bit 0

Pulse disable, configuration error

1 = on
0 = off

Bits 1-7

Not assigned

Bit 8

Reserved

Bit 9

Pulse disable, encoder limit frequency

1 = on
0 = off

Bits 10-12

Not assigned

Bit 13

Pulse disable abs. motor encoder
temperature

1 = on
0 = off

Bit 14

Pulse disable on motor temperature
warning

1 = on
0 = off

Bit 15

Not assigned

Concentricity monitoring tolerance

1615

Default value

Lower input limit

Upper input limit

Units

2.0

0.0

100.0

rpm

Active

at once

Load test: Setting the tolerance range for concentricity monitoring. If the tolerance range is
violated (underrange or overrange) by the actual speed, counter "Diagnostics concentricity
monitoring" MD 1724 is incremented.

Bits variable message function

1620

Default value

Lower input limit

Upper input limit

Units

0000

0000

FFFF

Hex

Active

at once

Input bit field for controlling the variable message function.

©

Siemens AG 1992 All Rights Reserved 6FC5197- AA50

7–139

SINUMERIK 840C (IA)

Advertising
This manual is related to the following products: