6 NC Machine Data (NC MD), NC Setting Data (NC SD)

01.99

6.7.1 Axis-specific MD bits 2 (axial bits 2)

7

6

5

4

3

2

1

0

Bit No.

NC MD

1828*

Linear scale

(as from
SW 6.3)

Extended

parameter

set switch-

over (as from

SW 4)

NC MD 1828* bit 1:

This bit is only used for linear axes with ENDAT absolute encoders.

Bit 1 Bit 1=1 Linear scale not available. Maximum traversing range of this axis is then + / -

half of the maximum traversing range of the absolute encoder, symmetrical
around the zero position.

Bit 1=0 Linear scale available. The traversing range of this axis does not have to be

set symmetrically around the zero position. The maximum traversing range is
calculated to: + / - the traversing range of the absolute encoder/8* MD 1264*.

Bit 0 Bit 0=1 Extended parameter set switchover

Bit 0=0 Gear stages/parameter set switchover as in SW 1 - 3

Parameter set switchover is only possible with the option bit.

Active: After Power On

1832*

(from

SW 6.3)

Actual value

reading axis

2nd measur-

ing system

Actual value

reading axis
1st measur-

ing system

Multiple

assignment

2nd measur-

ing system

Multiple

assignment

1st measur-

ing system

PT2 contour

monitoring

active

NC MD

Bit No.

7

6

5

4

3

2

1

0

Bit 4 Bit 4=1 This axis is an actual value reading axis at the 2nd measuring system

connection (NC MD 1388*). The restrictions for reading axes therefore apply.

Bit 4=0 This axis has unrestricted use of the 2nd measuring system connection (NC

MD 1388*)

Bit 3 Bit 3=1 This axis is an actual value reading axis at the 1st measuring system

connection (NC MD 200*). The restrictions for reading axes therefore apply.

Bit 3=0 This axis has unrestricted use of the 1st measuring system connection (NC

MD 200*).

Bit 2 Bit 2=1 Multiple assignment of the 2nd measuring system connection of this axis (NC

MD 1388*) is permitted with digital drives. When using this measuring system
connection only one of these axes must not have a Bit 4 setting under MD
1832*. Bit 4 must be set on all others.

Bit 2=0 Multiple assignment of the 2nd measuring system connection of this axis (NC

MD 1388*) is not permitted.

Bit 1 Bit 1=1 Multiple assignment of the 1st measuring system connection of this axis (NC

MD 200*) is permitted with digital drives. When using this measuring system
connection only one of these axes must not have a Bit 3 setting under MD
1832*. Bit 3 must be set on all others.

Bit 1=0 Multiple assignment of the 1st measuring system connection of this axis (NC

MD 200*) is not permitted.

Bit 0 Bit 0=1 The new PT2 contour monitoring is activated even if 0 is set under NC MD

3420*. By entering a compensation value between 1 and 600 under NC MD
3420*, the PT2 following error model will be calculated according to this
compensation value.

Bit 0=0 The existing contour monitoring is activated as long as 0 is set under NC MD

3420*. By entering a compensation value between 1 and 600 under NC MD
3420*, this will activate the improved PT1 contour monitoring.

Active:

After Power On

6–190

©

Siemens AG 1992 All Rights Reserved 6FC5197- AA50

SINUMERIK 840C (IA)