6 NC Machine Data (NC MD), NC Setting Data (NC SD)

07.97

6.2 General machine data (general data)

Minimum reduction factor (as from SW 6)

335

Default value

Lower input limit

Upper input limit

Units

100

0

100

%

Active

at once

The minimum reduction factor is entered as a percentage in the general machine data.

The actual path velocity is adapted to the new set path velocity by way of the actual path
acceleration.

Velocity increase factor (as from SW 6)

336

Default value

Lower input limit

Upper input limit

Units

0

0

10 000

0.01·%/T

IPO

Active on

at once

The velocity increase factor is the value in percent per IP cycle by which the reduction factor
is again increased to 100% after failure to reach the hysteresis threshold of the following axis
velocity.

2nd MCS offset in X coordinates (as from SW 6)

337

Default value

Lower input limit

Upper input limit

Units

0

0

99 999 999

MS

POWER ON

Note:

For further information see description of the function collision monitoring.

2nd MCS offset in Y coordinates (as from SW 6)

338

Default value

Lower input limit

Upper input limit

Units

0

0

99 999 999

MS

POWER ON

Note:

For further information see description of the function collision monitoring.