12.35 Uninterruptible power supply (UPS) (as from SW 6.3) (Express shutdown)

12.35

Uninterruptible power supply (UPS) (as from SW 6.3)
(Express shutdown)

General

When the 840 C control is not purposely, i.e. properly ramped down but instead just turned off,
general problems can occur in the operating system. E.g. opened data files may not be closed
properly leading to inventory data inconsistencies. In a worst case scenario, the file system of
the hard disk could become inconsistent during a momentary write access to the hard disk.
The danger in such cases is that the MMC may not be able to boot at the next POWER ON.

With the help of a standard UPS (approx. 300 W) it is possible to switch off or ramp down
(express shutdown) the NC in a controlled manner.

Express shutdown function diagram

UPS signals

”Power failure”

Input X 121 5/6

UPS

CSB

I/O

NCK

MD 5030
Bit 0 - bit 7

MMC

PLC

basic

program

Bit 6 Bit 7

FY 22

PLC

user

program

I/O

FX 73/74

I code
express
shutdown

Message

to USP

”Data saved”

Output

X121 24/25

Configuration of the express shutdown

Configuration options as follows:

Connection via special I/O on the central service board (CSB)
Connection via PLC inputs/outputs

12–354