8 PLC Machine Data (PLC MD)

8.5 PLC MD for the operating system (system bits)

6026

DL 13

Enable

serial

interface

DB37

Enable init

in same
channel

Deselect

autom. NC

START

INHIBIT

with MDA

Save flag

area

Access to

PLC data

inhibited

with @

Command

channel
enabled

PLC MD

DB63

DW No.

Bit No.

7

6

5

4

3

2

1

0

Default value:

1000 000

Bit 7

When bit 7 is set, data can be read in and out via the computer link
interface with DB 37.

Bit 6 = 1:

Funktion Init im eigenen Kanal wird freigegeben.

Bit 5 = 1:

NC start is issued to all channels (even if ”NC start inhibit” is active).
It is up to the passed to make sure that NC start is not passed to the NC
(DB 10-13, D 20).

Bit 3 = 0:

Save flags 224 - 255 (default setting) when changing processing level

Bit 3 = 1:

Save flags 200 - 255 when changing processing level

Bit 5 = 0:

On MDA mode, NC start is only passed to the selected channel. NC start
is not passed to those channels signalling ”NC start inhibit”
(DBs 10-13, D 16-15).

Note:

The MD is not active when using the ”Overstore” function. With ”Overstore”, NC start is
always prevented from becoming active in a non-selected channel.

Bit 2

Access to PLC data over @ commands is disabled.

Bit 1

The command channel function is enabled. The number of user interfaces
is specified in PLC MD 33. See PLC MD 33.

6029

DR 14

Signal T/H

word routing

target

channel

suppressed

T/H

word

routing

active

PLC MD

DB63

DW No.

Bit No.

7

6

5

4

3

2

1

0

Default value:

0

Bit 0

Bit = 0

T and H words are output to the programmed channel DB only. Also see
the Interface Description.

Bit = 1

T/H words can be routed to different channel DBs over the extended T/H
address.

Bit 3

As long as interface signal DB 10 to 13, DR 63.6 is set to "1", machine data bit
6029.3 has the following effect:

Bit = 0

The signal "Route T/H word" from the source channel to the programmed
target channel is suppressed.

Bit = 1

The signal "T/H word routing" is suppressed in the target channel.