7 Drive Machine Data (SIMODRIVE Drive MD)

7.4.3 Diagnosis/service MD (data description - as from SW 3)

Module order code (as from SW 4)

10100-

10114

10119

1)

Default value

Lower output limit

Upper output limit

Units

0

0

65535

-

Active on

Power on

The "Module order code" machine data contains the selected module in the form of a decimal
code number. In the case of two-axis modules, the data contains two sets of information.
Machine data 10100 to 10114 are assigned to physical addresses 1 to 15.

Power section code (as from SW 4)

10200-

10214

10229

1)

Default value

Lower output limit

Upper output limit

Units

0000

0000

FFFF

Hex

Active on

Power on

The "Power section code" machine data contains the required or used amperages for the
selected module according to the hexadecimal code number (see also MD 1106). In the case
of two-axis modules, the data contains two sets of information. Machine data 10200 to 10214
are assigned to physical addresses 1 to 15.

Data version (as from SW 4)

10900

Default value

Lower output limit

Upper output limit

Units

Active

Firmware version (as from SW 4)

10901

Default value

Lower output limit

Upper output limit

Units

Active

Firmware data (as from SW 4)

10902

Default value

Lower output limit

Upper output limit

Units

Active

Hardware configuration (as from SW 4)

10903

Default value

Lower output limit

Upper output limit

Units

Active

10903.0

Mixed I/O

10903.1

DCM

1)

As from SW 5

©

Siemens AG 1992 All Rights Reserved 6FC5197- AA50

7–169