7 Drive Machine Data (SIMODRIVE Drive MD)

07.97

7.3.2 Drive MD (data description)

Breakdown

torque limitation

1/n

2

Power

limitation

1/n

Resultant
torque limit
value

MD 1145

Constant

torque range

Speed

MD 1235

Reduction factor MD 1236

with selection of 2nd power

limit

Additional limitation

through MD 1237 in
generator operation

Torque limitation

MD 1230

Reduction factor MD 1231

with selection of

2nd torque limit

Reduction factor MD 1223 in

generator operation

Additional limitation through

MD 1239 in set-up mode

Constant power range

Power limitation

Breakdown torque

limitation

2nd torque limiting value

1231

Default value

Lower input limit

Upper input limit

Units

100.0

5.0

100.0

%

Active

at once

The 2nd torque limit value entered in MD 1231 acts as a reduction factor referred to the 1st
torque limit value (MD 1230). It becomes active only if the 2nd torque limit value is selected
via the PLC control word and the motor speed exceeds the value set in MD 1232 with
hysteresis (MD 1234).

Switching speed from MD 1230 to MD 1231

1232

Default value

Lower input limit

Upper input limit

Units

6 000.0

0.0

50 000.0

rev/min

Active

at once

Input of speed above which switchover from the 1st torque limit to the 2nd torque limit (MD
1231) can take place. A settable hysteresis (MD 1234) is applied during switchover. The 2nd
torque limit value is activated only if the motor speed exceeds the speed threshold with
hysteresis and if the 2nd torque limit value has been selected via the PLC control word.