11 Data Backup/CPU Replacement

01.99

11.1.5 Restarting after MMC CPU replacement

11.1.5 Restarting after MMC CPU replacement

Loading using the streamer (Restore)

Control ”ON” after MMC CPU replacement

MMC CPU without

system software

MMC CPU with

system software

Once reading in has been completed, switch system off and then on again

Load PLC MD from disk via Diagnosis/Startup/Machine data/File function

Carry out a PLC restart via PG or

Diagnosis/General reset mode

If required load data from disk to NCK

Different software versions
1) MMC CPU without system software:

Insert backup tape ”Complete system” and read in.

2) MMC CPU with system software and same software version:

Insert backup tape ”Complete system” (same version) and
read it in using a ”Restore” system or read in backup tape
”User data” using ”Restore user data”.

3) MMC CPU with system software of a different version:

”Uninstall MMC system” may have to be carried out before reading in.
Proceed as in 2). Take note of upgrading instructions.

4) MMC CPU with user data ”SW upgrading instructions”:

See upgrading instructions
Save user data
Proceed with ”Uninstall MMC system”
Read in tape with new software version via ”Install MMC system”
Read in user data via ”Restore user data”.

After switching on

”Backup” menu is offered

After switching on in the ”Diagnosis”,

”Startup” operating area,

select startup of the”Backup” menu

Set date/time

Connect streamer and set up the respective type of streamer

Select ”Restore/Backup”

11–8

© Siemens AG 1992 All Rights Reserved 6FC5197- AA50

SINUMERIK 840C (IA)