Siemens SINUMERIK 840C User Manual

Page 413

Advertising
background image

6 NC Machine Data (NC MD), NC Setting Data (NC SD)

07.97

6.12.1 NC setting data (NC SD)

Axial bits

7

6

5

4

3

2

1

0

Bit No.

SD MD

560*

Scale factor

active on

machine

Rapid

override not

active

Feedrate

override not

active

Bit 2

The scale factor (G51) is active during machining.

Bit 1

Override switch for rapid traverse no longer active in the axis in question.

Bit 0

Override switch for feedrate no longer active in the axis in question.

7

6

5

4

3

2

1

0

Bit No.

SD

564*

10000

1000

100

10

1

Increments per handwheel pulse

Evaluation of handwheel pulses (applies to both handwheels) per axis

Bit 0=1

1 increment per handwheel pulse (display resolution)

Bit 1=1

10 increments per handwheel pulse (display resolution)

Bit 2=1

100

"..."

Bit 3=1

1000

"..."

Bit 4=1

10000

"..."

Spindle converter setting data

7

6

5

4

3

2

1

0

Bit No.

SD

600*

to

625*

Spindle converter

The setting data are stored as follows in binary format.

SD 600*

1st progr. spindle channel-specific

SD 602*

1st real spindle channel-specific

SD 604*

2nd progr. spindle channel-specific

SD 606*

2nd real spindle channel-specific

SD 608*

3rd progr. spindle channel-specific

SD 610*

3rd real spindle channel-specific

SD 612* spindle conversion list on/off (1=on, 0=off)

These setting data can be altered via @311, @312, @411, @412 / PLC / RS 232 C (V24).

The spindle converter only operates in the automatic, teach-in and MDA modes but not with
overstore.

The automatic basic display does not show that the spindle converter is active.

Note:

See Functional Description for detailed description.

6–228

©

Siemens AG 1992 All Rights Reserved 6FC5197- AA50

SINUMERIK 840C (IA)

Advertising
This manual is related to the following products: