8 PLC Machine Data (PLC MD)

8.2 PLC MD for the operating system (system data)

Example:

Value in PLC MD 11 = 71 when 1st machine control panel in PLC MD 128 is set to start
address 64.

I byte 0
:
:
:
I byte 71
I byte 72
:
:
I byte 127

Signals from the machine

Can be used as additional flag area

Max. 128 bytes on 135 WB

Reserved

14

Default value

Lower input limit

Upper input limit

Units

0

DB 60

DW 14

Reserved

13

DB 60

DW 13

No. of wait cycles for assigned UI

17

Default value

Lower input limit

Upper input limit

Units

1

0

10

DB 60

DW 17

This timeout is specified as the number of PLC cycles that are allowed to elapse before the
user interface (UI) is enabled, and applies to all user interfaces on a PLC. When the timeout
has expired, a negative acknowledgement is sent in response to a frame sent to the user
interface.

Default value:

1

i.e. the user interface must be free again after one PLC cycle

Max. input value:

10 i.e. the user interface must be free again after ten PLC cycles

See also Computer Link

No. of the UI during synchronization

18

Default value

Lower input limit

Upper input limit

Units

0

0

31

DB 60

DW 18

A frame sent to the host computer can be output only via this user interface during
synchronization. See Computer Link.