7 Drive Machine Data (SIMODRIVE Drive MD)

09.95

7.2.2 FDD MD (data description - SW 3)

Speed actual value

1707

Default value

Lower output limit

Upper output limit

Units

0.0

0000

32 767.0

rev/min

Active

at once

This machine data is used to display the actual speed value and represents the unfiltered
actual speed value. Time-synchronous unlatching (scanning) of machine data MD 1706,
MD 1707 and MD 1708 is not provided. The appropriate machine data is unlatched by the
MMC request "Read variables" via the STF ES communications interface.

Smoothed current actual value

1708

Default value

Lower output limit

Upper output limit

Units

0.0

0000

32 767.0

%

Active

at once

This machine data is used to display the smoothed current actual value. The torque-producing
current actual value is smoothed by a PT1 element with constant coefficients. These
coefficients correspond to time constants of 20 ms (with a current controller cycle of 62.5

µ

s)

and 40 ms (with a current controller cycle of 125

µ

s). In this case, the smoothed current actual

value is displayed as a percentage. 100 % corresponds to the maximum current of the power
section (e.g. with an 18/36A power section 100 % = 36A RMS).

Significance current representation

1710

Default value

Lower output limit

Upper output limit

Units

0.0

0

32 767.0

µ

A

Active

at once

This machine data is used to display the significance of the current representation. The
significance of bit 0 (internal current actual value representation) is shown to the user to allow
allocation of the internal current status representation to the physical ampere values. The
maximum power section current is present internally in normalized representation.

Note:

This machine data is calculated only once during ramp-up; its value cannot therefore be
changed during operation.

Significance speed representation

1711

Default value

Lower output limit

Upper output limit

Units

0.0

0

32 767.0

rev/min

Active

at once

This machine data is used to display the significance of the speed representation. The
significance of bit 0 (internal speed actual value representation) is shown to the user to allow
allocation of the internal speed status significance to the physical revolution values. A speed is
present internally in the units of the encoder system and referred to the current speed
controller clock cycle.

7–72

©

Siemens AG 1992 All Rights Reserved 6FC5197- AA50