7 Drive Machine Data (SIMODRIVE Drive MD)

7.3.2 Drive MD (data description)

CPU load (as from SW 6)

1735

Default value

Lower output limit

Upper output limit

Units

0

0

100

%

Active

at once

The processor capacity displays the remaining available CPU time online.

Measuring circuit type indirect measuring system

1790

Default value

Lower output limit

Upper output limit

Units

0

0

32 767

Active

at once

This machine data displays the measuring circuit code number of the indirect measuring
system (motor).

Value table:

0

Voltage raw signals

1-7

Reserved

Measuring circuit type direct measuring system

1791

Default value

Lower output limit

Upper output limit

Units

0

-1

32 767

Active

at once

This machine data displays the measuring circuit code number of the direct measuring system
if one is inserted.

Value table:

-1

No measuring system present

0

Voltage raw signals

1

Current raw signals (FDD)

2-7

Reserved

Data version

1797

Default value

Lower output limit

Upper output limit

Units

0

0

32 767

Active

at once

Output of present data version (machine data list).

©

Siemens AG 1992 All Rights Reserved 6FC5197- AA50