6 NC Machine Data (NC MD), NC Setting Data (NC SD)

6.2 General machine data (general data)

Number of Execution Memory Sectors

30

Default value

Lower input value

Upper input value

Units

10

5

1 000

Sector

Active on

Power On

Active: on POWER ON

When ”Working from external” or from the hard disk, the part program is read into a circular
buffer which executes the program at the same time. The circular buffer is part of the part
program memory. The size of the circular buffer is defined in NC MD 30 as number sectors
(1 sector = 507 bytes).

Active RS232C (V.24) or Sinec H1

External mass

storage

Unassigned circular buffer

Block pointer for execute

Full circular buffer

Block pointer for reading in

Circular

buffer

Program

execution

Sinumerik 840C

If the specified sectors are not available to the circular buffer on NC Start (either occupied by
part programs or part program memory too small), the circular buffer is reduced to the
maximum possible number of sectors by the control.

Additional machine data: (MD 130*, MD 5148-5152, option bit)

If processing is to take place from more than 1 interface, an appropriate area is reserved for
each of these interfaces.

©

Siemens AG 1992 All Rights Reserved 6FC5197- AA50