background image

NCK power
ON

Start-up end

09.95

Siemens AG 2001

All Rights Reserved

6FC5197–

j

AA50

4–8

SINUMERIK 840C (IA)

NCK power ON without voltage failure.

Features:

S

MD are activated.

S

Reference point values are lost.

S

PC data are not updated.

Terminate the machine data dialog (MDD).

4.2

NC Service

For drive optimization and error diagnosis it is necessary to check the data trans-
mitted from the NC to the axes or spindles and from the axis or spindles to the
NC.

The following service data for axes are displayed:

S

Following error in position control resolution (limit = 2 position control resolu-
tion units)

S

Absolute actual value in position control resolution units
True position of the axes on the machine.

S

Setpoint in position control resolution units
Default which has been determined by the control system on the basis of pro-
gramming or setpoint position entered manually.
Normally, setpoint and absolute actual value are identical. In standstill, the
difference (following error) can be compensated with the drift compensation.

S

Abs. compensation value
Sum of IKA and temperature compensations.

S

Speed setpoint in 0.01 % of the maximum speed
Digital value which has been determined by the control system (maximum
value see NC-MD 268*). This is converted into an analog value (0 V to 10 V)
on the measuring circuit module and output as speed setpoint to the drive.

S

Partial actual value in position control resolution units
Pulses per interpolation clock sent by the measuring system (standard 16
ms).

S

Partial setpoint in position control resolution units.
Partial setpoints per interpolation time sent by the interpolator to the position
control (standard 16 ms).

S

Contour monitoring
The current contour deviation is displayed with this value (fluctuations of the
following error due to adjustments on the speed controller caused by settling
due to load changes).

S

Synchronous run error
Deviation between leading axis and following axis.

S

Parameter set position control.