Siemens SINUMERIK 840C User Manual

Page 643

Advertising
background image

Meas.
parameter

09.95

Siemens AG 2001

All Rights Reserved

6FC5197–

j

AA50

9–22

SINUMERIK 840C (IA)

Notes

In order to ensure a more gentle machine setting, the lowest possible values
should be set for amplitude and offset. Excessively high input values result in
the output of alarm messages such as “1560 Speed setpoint alarm limit violated”.

Following error, speed actual value or position actual value are the quantities
which can be measured. The position setpoint and the active measuring system
are recorded in each case.

D

3rd measuring type: Setpoint ramp

The transient or positioning of the position control in the time range can be as-
sessed with the ramp stimulation function. If an offset value other than zero is
input, the step change is stimulated during traversal. The displayed position ac-
tual value does not include this speed offset. The effect of the setpoint smoothing
filter can be checked on the basis of the position setpoint characteristic.

You can select the menu with the parameters for measuring the position control
loop with this softkey.

Note

You enter the measurement parameters in the selected display. These parame-
ters are managed internally as configuration data rather than machine data, i.e.
they are not initialized when the machine runs up. Data can be input in two diffe-
rent ways:

S

Manual input

S

Input by loading of an existing, complete data set with the aid of file functions

Measurement

as for measurement type setpoint step change

parameter settings

Note

as for measurement type setpoint step change

9 Drive Servo Start-Up Application (as from SW 3)

9.2.6 Position control loop (axis and spindle) – measurement parameters (9 basic settings – as from SW 3)

07.97

Advertising
This manual is related to the following products: