Siemens SINUMERIK 840C User Manual

Page 306

Advertising
background image

09.01

6 NC Machine Data (NC MD), NC Setting Data (NC SD)

6.6.1 General MD bits (general bits)

7

6

5

4

3

2

1

0

Bit No.

NC MD

5186

Fast block

change (up

to SW 2)

G176

active (up

to SW 3)

Axis conv.
spindle
conv. active
(as from
SW 2)

Several
block skip
levels (as
from SW 2)

Program
coordina-
tion (as
from SW 2)

Default value:

0

Active:

In the block prior to decoding

Bit 4

Bit 4=1

FIFO active (see Section entitled ”Functional Descriptions”)

Bit 3

Bit 3=0

Programming function G176 cannot be used.

Bit 3=1

Programming function G176 is used to 'freeze' the zero offsets for the
angles of rotation and the tool length compensations, i.e. these values
are not updated in every block. This reduces the amount of time
required for block changes. G176 can be revoked with G175 (initial
setting).

Bit 2

Bit 2=1

The ”Axis converter/Spindle converter” function is active (see Section
entitled ”Functional Descriptions”).

Bit 1

Bit 1=1

Function BLOCK SKIP LEVELS is active (refer also to
SINUMERIK 840C Programming Guide).
Active:

immediately

Bit 0

Bit 0=1

Program coordination permits the user to program coordination
commands in plaintext in the part program. The coordination commands
are transferred to the NC PLC interface. The PLC performs the
coordination itself (see also SINUMERIK 840C Programming Guide).
Active:

On POWER ON

7

6

5

4

3

2

1

0

Bit No.

NC MD

5188

Double

channel

displ. (as

from SW 2)

Bit 0

MCD (Multi-channel display)
Several channels can be displayed at any one time on the screen for
operator support when multiple machine tools are used. The operator
can then check the allocation of programs that run simultaneously and
test the synchronization marks in test mode.

Active:

POWER ON

7

6

5

4

3

2

1

0

Bit No.

NC MD

5189

MD 161

enabled

(from SW

6.4)

Extended

program

view

(from SW

6.3)

Suppres-

sion of

alarm 3265

(from SW

6.03.57)

Name of

default

workpiece

(from

SW 5)

Default value:

0

Bit 5

Bit 5=1

Alarm 3265 is suppressed

Bit 5

Bit 5=0

Alarm 3265 is active

©

Siemens AG 1992 All Rights Reserved 6FC5197- AA50

6–121

SINUMERIK 840C (IA)

Advertising
This manual is related to the following products: