Siemens SINUMERIK 840C User Manual

Page 432

Advertising
background image

10.94

7 Drive Machine Data (SIMODRIVE Drive MD)

7.1.2 MSD MD (data description - SW 3)

Grading torque setpoint filter motor 1

104

Default value

Lower input limit

Upper input limit

Units

1.00

0.10

10.00

Active

at once

Input of filter quality for the bandstop in the torque setpoint channel (see MD 117).

1.00: Basis quality=1

Correction P-gain current controller motor 1

116

Default value

Lower input limit

Upper input limit

Units

0

-255

255

Active

at once

The current controller P-gain, which is calculated according to the motor, converter and
converter switching frequency, can be corrected by an offset in this machine data. A positive
value in MD 116 results in a higher gain and a negative value in a lower gain than the gain
value calculated. The total gain obtained by adding the calculated value and the correction in
MD 116 is displayed in MD 316.

Selection torque setpoint filter motor 1

117

Default value

Lower input limit

Upper input limit

Units

0000

0000

0001

Hex

Active

at once

The digital filter is activated and deactivated in this machine data. A digital filter can be
implemented in the torque setpoint channel with machine data MD 103, MD 104 and MD 117.

0:

Digital filter deactivated

1:

Digital filter activated

Type torque setpoint filter motor 1

118

Default value

Lower input limit

Upper input limit

Units

0000

0000

0001

Hex

Active

at once

The filter type is selected in this machine data (see MD 117).

0:

Bandstop characteristic

1:

Low-pass characteristic

©

Siemens AG 1992 All Rights Reserved 6FC5197- AA50