Siemens SINUMERIK 840C User Manual

Page 298

Advertising
background image

12.93

6 NC Machine Data (NC MD), NC Setting Data (NC SD)

6.6.1 General MD bits (general bits)

7

6

5

4

3

2

1

0

Bit No.

NC MD

5080

5081

5082

to

5089

Transformation channel number (3rd block)

G function for transformation selection (3rd block)

Axis name (3rd block)

See MD 5060
MD for 3rd TRANSFORMATION BLOCK.

7

6

5

4

3

2

1

0

Bit No.

NC MD

5090

to

5139

These NC MDs are intended for future expansion only and cannot be used at the
present time.

Default values

All bits 0 for

NC MD

5070, 5071, 5080, 5081, 5090, 5091,
5100, 5101, 5110, 5111, 5120, 5121, 5130, 5131

Default values

All bits 1 for

NC MD

5072-5079, 5082-5089, 5092-5099,
5102-5109, 5112-5119, 5122-5129, 5132-5139

These NC MDs must not be changed during the transformation option. They are verified on
Power On and alarm 3087 issued in the event of a verification error.

Active:

On POWER ON or on a warm restart

©

Siemens AG 1992 All Rights Reserved 6FC5197- AA50