Siemens SINUMERIK 840C User Manual

Page 444

Advertising
background image

10.94

7 Drive Machine Data (SIMODRIVE Drive MD)

7.1.2 MSD MD (data description - SW 3)

Address for stop condition

210

Default value

Lower input limit

Upper input limit

Units

0000

0000

FFFF

Hex

Active

at once

Input of address for the variable which is significant for stopping the recording (see also
MD 206).

Threshold for stop condition

211

Default value

Lower input limit

Upper input limit

Units

0000

0000

FFFF

Hex

Active

at once

Input of threshold (value) with which the contents of the variable specified in MD 210 are
compared in order to stop the recording (see also MD 206).

Address for signal 1

212

Default value

Lower input limit

Upper input limit

Units

0C00

0000

FFFF

Hex

Active

at once

Input of address of recording signal 1 (see also MD 206).

Address for signal 2

213

Default value

Lower input limit

Upper input limit

Units

0C04

0000

FFFF

Hex

Active

at once

Input of address of recording signal 2 (see also MD 206).

Start output of recording

214

Default value

Lower input limit

Upper input limit

Units

0000

0000

0001

Hex

Active

at once

Input of start for the output of the transient recorder function (see also MD 206).

The contents of the recorder memory are output via 2 DACs as soon as the above machine
data is set to 1H. The output is repeated cyclically.

Shift factor signal 1

215

Default value

Lower input limit

Upper input limit

Units

0

0

15

Active

at once

Input of shift factor for signal 1 (see also MD 206). The top 8 bits from a 16-bit wide memory
location are output. This machine data specifies how often the value must be shifted to the left
beforehand.

©

Siemens AG 1992 All Rights Reserved 6FC5197- AA50

7–29

SINUMERIK 840C (IA)

Advertising