4 temperature compensation tc, 1 types of influence – Siemens SINUMERIK 840C User Manual

Page 962

Advertising
background image

09.95

12 Functional Descriptions

12.19.4 Temperature compensation TC

12.19.4

Temperature compensation TC

The TEMPERATURE COMPENSATION (TC) function

is available as an option.

With this compensation function, the compensation values applying to the current temperature
are transferred from the PLC to the NC via the command channel. The requisite compensation
values must have been calculated in the PLC beforehand by the machine manufacturer.

12.19.4.1 Types of influence

There are two different types of temperature influence:

Position-dependent influence on actual value

The temperature-related actual-value deviation for an axis can be represented by an error
curve. It can be assumed that the position-dependent expansion develops evenly from one
reference point. It can be approximated by means of a straight line of which the gradient is
determined by the temperature.

Reference
point

-x

+x

Error
(comp. value)

Error curve

ß

Position-independent influence on actual value

The measured axis actual value deviates by an absolute temperature-dependent value which is
not dependent upon the actual axis position. The characteristic of this error curve can likewise
be approximated by a straight line.

-x

+x

Reference
point

Error
(comp. value)

Error curve

Absolute compensation value