Siemens SINUMERIK 840C User Manual

Page 392

Advertising
background image

01.99

6 NC Machine Data (NC MD), NC Setting Data (NC SD)

6.9.1 MDs for collision monitoring

Protection dimensions in 3 coordinates not equal to 0:
Three-dimensional monitoring

Definition:

Two-dimensional protection zone to be mutually monitored for collision must be in the same
plane.

Assigned MCS (as from SW 6)

3840*

Default value

Lower input limit

Upper input limit

Units

0

0

3

Active on

POWER ON

with *= protection zone index:
1st protection zone=0
2nd protection zone=1 to
32nd protection zone=31

A machine coordinate system (MCS) must be assigned to each protection zone. These
assignments are made in the protection-zone-specific machine data:

Value range:

0/1 = 1st machine coordinate system
2

= 2nd machine coordinate system

3

= 3rd machine coordinate system

4

= 4th machine coordinate system

Note:

For more detailed information please see Functional Description.

3876*

Res.

Res.

Res.

Res.

Res.

Res.

Additive

protection

zone

adjustment

(as from

SW 6.3)

Protection

zone exists

MD No.

Bit No.

7

6

5

4

3

2

1

0

with *=protection zone index:
1st protection zone=0
2nd protection zone=1 to
32nd protection zone=31

Monitoring of a defined protection zone can be activated with this MD.

Bit 0

Bit 0=0

Protection zone does not exist

Bit 0=1

Protection zone exists

Active: POWER ON

Bit 1

Bit 1=0

Additive protection zone adjustment via setting data inactive

Bit 1=1

Additive protection zone adjustment via setting data active

©

Siemens AG 1992 All Rights Reserved 6FC5197- AA50