Siemens SINUMERIK 840C User Manual

Page 677

Advertising
background image

Function
parameters

09.95

Siemens AG 2001

All Rights Reserved

6FC5197–

j

AA50

9–56

SINUMERIK 840C (IA)

D

Neural QEC parameterization

You can select the menu with the function parameters for the neural QEC func-
tion with this softkey.

Fig. 9.31

Notes

You enter the function parameters in this display. If the neural QEC has not yet
been started up for this axis, all parameters are set to 0. Meaningful standard
parameter settings can be assigned by means of the file functions with “Load file:
STANDD_Q”. The current parameter settings are displayed if a data block is al-
ready stored in the boot file or if the neuronal network has been activated since
the last power ON for the axis displayed.

Function parameter

S

Max. acceleration (a

3

)

settings

This parameter defines the upper limit of the operating range. Values of > 0
may be entered. The default setting after “Load default” is 500 mm/s

2

.

S

Lower range limit (a1)
This parameter defines the limit of the lower acceleration range. Values of >0
and <100 may be entered. The default setting after “Load default” is 2 %.

S

Medium range limit (a2)
This parameter defines the limit of the medium acceleration range. Values of
>0 and <100 may be entered. The default setting after “Load default” is 60 %.

S

Direction dependence
This parameter determines the direction-specific compensation. The states
“yes” or “no” may be selected. The default setting after “Load default” is “no”.

S

Fine quantization
This parameter defines the fine quantization of the input quantity. Values of

9 Drive Servo Start-Up Application (as from SW 3)

9.5.4 Neural quadrant error compensation (QEC – SW 4)

10.94

Advertising
This manual is related to the following products: